About 77,000 results
Open links in new tab
  1. Introduction to Modbus and Modbus Function Codes

    Jan 30, 2023 · Introduction to Modbus and Modbus Function Codes Modbus is one of the oldest industrial communication protocols still in use today. Continue reading to find out how the …

  2. Modbus: The Original Industrial Fieldbus Protocol

    Sep 2, 2025 · This article introduces Modbus, an industrial protocol that laid the foundation for fieldbus communication in industrial systems.

  3. Making Modbus device communicate with a PC - Control.com

    Jul 26, 2007 · I am learning more about MODBUS, and I would like to know how I make the Modbus device communicate with the PC. Like for example, how do I gather outputs/inputs …

  4. Modbus client application | Automation & Control Engineering …

    Jan 9, 2024 · Open Modbus adds two other IEEE754 32 bit floating formats with its LE button which selects between Big Endian and Little Endian. Win-tech two standard FP formats …

  5. Modbus errors | Automation & Control Engineering Forum

    May 22, 2012 · Modbus Poll is the master and you must disconnect the existing master before using it. If the situation is that you actually use Modbus Poll as master the problem could be …

  6. Modbus over Ethernet | Automation & Control Engineering Forum

    Jun 25, 2008 · Modbus is a protocol. You can use Modbus protocol over Ethernet, it is then called Modbus TCP/IP. Commonly used by Schneider Electric, as Schneider bought the company …

  7. Modbus vs. Modbus/TCP Speed | Automation & Control …

    Dec 23, 2009 · The big difference (& problem) with Modbus/RTU is that it lacks a sequence number so when pushing Modbus/RTU for max performance with short time-outs etc, you risk …

  8. Sending strings over modbus | Automation & Control Engineering …

    Feb 24, 2010 · Hi, A customer has asked if he can read application information from the PLC (Version, author, project name etc) over modbus to display on his touch screen HMI. I am the …

  9. Siemens S7-1200 PLC modbus reading issues - Control.com

    Sep 3, 2024 · View attachment 4356 View attachment 4357 Hardware setup: we have the PLC connected to 2 modbus slaves. Slaveid 1 and Slaveid 2 the also RS485 blinks at the TxD at …

  10. Multiple Masters on a Modbus TCP / IP Network - Control.com

    Jul 28, 2011 · In a system with one PLC providing process control and monitoring a series of pump VFD's and process water chillers, we wish a second PLC to be "backup". If the main …